spacer image

Security-Observation Technology

SPECTRA Control Panels

  • SPECTRA Control Panel

    1727

    • 6 zone inputs
    • 8 user codes (no partitioning)
    • 2 PGM outputs and 1 alarm relay
    • 1 bell output and 1 auxiliary output
    • 1.5A switching power supply
    • No support for Spectra modules except keypads
  • SPECTRA Control Panel

    1728 1686V/H Контролен панел 12 зони ( 5 дублирани+2 клавиатурни), с възможност за делене на две независими системи, разширение с до 8 зони, 2 PGM, BUS технология, комуникатор, клавиатура 1686 V/ H, Кутия 11х11"

  • SPECTRA Control Panel

    1738 1686V/H Контролен панел 16 зони (7 дублирани + 2 клавиатурни), с възможност за делене на две независими системи, разширение с до 8 зони, 2 PGM, BUS технология, комуникатор, клавиатура 1686 V/ H, Кутия 11х11"

SPECTRA Control Panels SP Series

  • SPECTRA Control Panel SP

    SP5500

    • StayD mode
    • 4-wire expansion bus
    • 5 zone inputs or 10 with zone doubling, expandable to 32 zones
    • 2 on-board PGMs
    • Supports up to 16 PGMs
    • 2 Partitions
    • 32 User Codes
    • 1.1A switching power supply
    • In-field firmware upgradeable via a 307USB and WinLoad
    • Menu-driven programming for the Installer, Master and Maintenance codes
    • Multiple phone numbers: 3 for monitoring station, 5 for personal dialing and 1 for pager reporting
    • Automatic Daylight Savings Time feature
    • Push button software reset (reset to default values and restart)
    • Direct connect at 9.6k baud with WinLoad
    • 256 events buffered
    • Fits in 20cm x 25.5cm x 7.6cm (8in x 10in x 3in) and 28cm x 28cm x 7.6cm (11in x11in x 3in) metal boxes
  • SPECTRA Control Panel SP

    SP6000

    • StayD mode
    • 4-wire expansion bus
    • 8 zone inputs or 16 with zone doubling, expandable to 32 zones
    • 2 (+2 optional) on-board PGM outputs, positive or negative triggering
    • Supports up to 16 PGMs
    • 2 Partitions
    • 32 User Codes
    • 1.5A switching power supply
    • 1 alarm relay (optional)
    • In-field firmware upgradeable via a 307USB and WinLoad
    • Menu-driven programming for the Installer, Master and Maintenance codes
    • Multiple phone numbers: 3 for monitoring station, 5 for personal dialing and 1 for pager reporting
    • Automatic Daylight Savings Time feature
    • Push button software reset (reset to default values and restart)
    • Direct connect at 9.6k baud with WinLoad
    • 256 events buffered
    • Fits in 20cm x 25.5cm x 7.6cm (8in x 10in x 3in) and 28cm x 28cm x 7.6cm (11in x11in x 3in) metal boxes
  • SPECTRA Control Panel SP

    SP7000

    • StayD mode
    • 4-wire expansion bus
    • 16 zone inputs or 32 with zone doubling, expandable to 32 zones
    • 4 on-board PGM outputs, positive or negative triggering
    • Supports up to 16 PGMs
    • 2 Partitions
    • 32 User Codes
    • 1.5A switching power supply
    • 1 alarm relay
    • In-field firmware upgradeable via a 307USB and WinLoad
    • Menu-driven programming for the Installer, Master and Maintenance codes
    • Multiple phone numbers: 3 for monitoring station, 5 for personal dialing and 1 for pager reporting
    • Automatic Daylight Savings Time feature
    • Push button software reset (reset to default values and restart)
    • Direct connect at 9.6k baud with WinLoad
    • 256 events buffered
    • Fits in 20cm x 25.5cm x 7.6cm (8in x 10in x 3in) and 28cm x 28cm x 7.6cm (11in x11in x 3in) metal boxes
spacer image